ยี่ห้อ (Brand): FLUKE รุ่น (Model): 572-2 ผลิตประเทศ (Origin): Designed in USA รับประกัน (Warranty): 1 ปี
รายละเอียด:
The Fluke 572-2 High-Temperature Infrared Thermometer is the one product you can use in high-temperature industrial environments all around the world. Whether you work in power utility, metal refining and smelting, glass, cement or petrochemical environments, the 572-2 allows you to carry the most trusted name in test tools anywhere you need accurate, high-temperature and high distance-to-spot measurements.
With a straight-forward user interface and soft-key menus, the Fluke 572-2 makes even complex measurements easy. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button.
With a rugged, easy-to-use, ergonomic design, the Fluke 575-2 can stand up to tough industrial, electrical, and mechanical environments.
Measure -30 °C to 900 °C (-22 °F to 1652 °F)
60:1 distance to spot ratio with dual laser sighting for fast, accurate targeting
Multi-language interface (user select)
Current Temperature plus MAX, MIN, DIF, AVG temperature displays
Compatible with standard mini-connector K-type thermocouples, including ones you already own and have installed
Adjustable emissivity and predefined emissivity table
Infrared and thermocouple temperature on backlit display
Last reading Hold (20 seconds)
High and low temperature alarm
Data storage and review (99 data sets)
Tripod mount
12 or 24 hour clock
USB 2.0 computer interface cable
FlukeView® Forms documenting software
Infrared Measurements
Infrared temperature range
-30 °C to 900 °C (-22 °F to 1652 °F)
IR accuracy (calibration geometry with ambient temperature 23 °C ± 2 °C)
≥ 0°C: ± 1°C or ± 1 % of the reading, whichever is greater
≥-10 °C to <0 °C: ±2°C
<-10°C: ±3 °C
≥32°F: ± 2°F or ± 1% of the reading, whichever is greater
≥14 °F to <32 °F: ±4 °F
<14 °F: ±6 °F
IR repeatability
±0.5 % of reading or ±0.5 °C (±1 °F), whichever is greater
Display resolution
0.1 °C / 0.1 °F
Distance: Spot
60:1 (calculated at 90 % energy)
Minimum spot size
19 mm
Laser sighting
Offset dual laser, output <1 mW
Spectral response
8 μm to 14 μm
Response time (95 %)
<500 ms
Emissivity
Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
Contact Measurements
K-type thermocouple input temperature range
-270 °C to 1372 °C (-454 °F to 2501 °F)
K-type thermocouple input accuracy (with ambient temperature 23 °C ± 2 °C)
<-40 °C: ±(1 °C + 0.2 °/1 °C)
≥-40 °C: ±1 % or 1 °C, whichever is greater
<-40 °F: ±(2 °F + 0.2 °/1 °F)
≥-40 °F: ±1 % or 2 °F, whichever is greater
K-type thermocouple
0.1 °C/0.1 °F
K-type thermocouple repeatability
±0.5 % of reading or ±0.5 °C (±1 °F), whichever is greater
Measurement Options
Hi/Low alarms
Audible and two-color visual
Min/Max/Avg/Dif
Yes
Switchable celsius and fahrenheit
Yes
Backlight
Two levels, normal and extra bright for darker environments
Probe input
K-type thermocouple simultaneous display of probe and IR temperature
Trigger lock
Yes
Data storage
99 points
Display
Dot matrix 98 x 96 pixels with function menus
Communication
USB 2.0
K-Type Thermocouple Specifications
Measurement range (bead probe)
-40 °C to 260 °C (-40 °F to 500 °F)
Accuracy
±1.1 °C (±2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F). Typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)
Cable length
1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
General Specifications
Safety and compliance
IEC 60825-1
FDA Laser Class II
IEC 61326-1
CE Complaint
CMC # 01120009
Operating temperature
0 °C to 50 °C (32 °F to 122 °F)
Storage temperature
-20 °C to 60 °C (-4 °F to 140 °F)
Relative humidity
10 % to 90 % RH non-condensing up to 30 °C (86 °F)
Operating altitude
2000 meters above mean sea level
Weight
0.322 kg (0.7099 lb)
Power
2 AA batteries
Battery life
8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle (thermometer continuously on)