Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital:
6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating Temperature
-10 °C to + 50 °C
Storage Temperature
-40 °C to + 60 °C
Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range:
600.0 mV
Resolution:
0.1 mV
Accuracy:
± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:
6.000 V / 0.001 V
Range/Resolution:
60.00 V / 0.01 V
Range/Resolution:
600.00 V / 0.1 V
Accuracy:
± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:
600.0 V
Resolution:
0.1 V
Accuracy:
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:
600.0 mV
Resolution:
0.1 mV
Accuracy:
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:
6.000 V / 0.001 V
Range/Resolution:
60.00 V / 0.01 V
Range/Resolution:
600.0 V / 0.1 V
Accuracy:
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:
600 Ω
Resolution:
1 Ω
Accuracy:
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:
600.0 Ω / 0.1 Ω
Range/Resolution:
6.000 kΩ / 0.001 kΩ
Range/Resolution:
60.00 kΩ / 0.01 kΩ
Range/Resolution:
600.0 kΩ / 0.1 kΩ
Range/Resolution:
6.000 MΩ / 0.001 MΩ
Accuracy:
0.9 % + 1
Range/Resolution:
40.00 MΩ / 0.01 MΩ
Accuracy:
1.5 % + 2
Diode Test
Range/Resolution:
2.000 V / 0.001 V
Accuracy:
0.9% + 2
Capacitance
Range/Resolution:
1000 nF / 1 nF
Range/Resolution:
10.00 μF / 0.01 μF
Range/Resolution:
100.0 μF / 0.1 μF
Range/Resolution:
9999 μF / 1 μF
Range/Resolution:
100 μF to 1000 μF
Accuracy:
1.9% + 2
Range/Resolution:
> 1000 μF
Accuracy:
5% + 20%
LoZ capacitance
Range:
1 nF to 500 μF
Accuracy:
10% + 2 typical
Temperature2 (Type-K thermocouple)
Range/Resolution:
-40 °C to 400 °C / 0.1 °C
Accuracy:
1% + 102
Range/Resolution:
-40 °F to 752 °F / 0.2 °F
Accuracy:
1% + 182
AC μamps true-rms (45 Hz to 500 Hz)
Range/Resolution:
600.0 μA / 0.1 μA
Accuracy:
1.0% + 2
DC μamps
Range/Resolution:
600.0 μA / 0.1 μA
Accuracy:
1.0% + 2
Hz (V or A input)2
Range/Resolution:
99.99 Hz / 0.01 Hz
Range/Resolution:
999.99 Hz / 0.1 Hz
Range/Resolution:
9.999 Hz / 0.001 Hz
Range/Resolution:
50.00 Hz / 0.01 Hz
Accuracy:
0.1% + 2
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F